JOHNSON MATTHEY CATALOG CHEMICALS -- CARBON POWDER ULTRA SUPERIOR, 14734 -- 6810-00N020723
=====================  Product Identification  =====================

Product ID:CARBON POWDER ULTRA SUPERIOR, 14734
MSDS Date:12/14/1987
FSC:6810
NIIN:00N020723
=== Responsible Party ===
Company Name:JOHNSON MATTHEY CATALOG CHEMICALS
Address:152 ANDOVER STREET
City:DANVERS
State:MA
ZIP:01923
Country:US
Info Phone Num:508-777-1970
Emergency Phone Num:508-777-1970
CAGE:0JVJ1
=== Contractor Identification ===
Company Name:JOHNSON MATTHEY CATALOG CO INC ALFA AESAR
Address:30 BOND ST
Box:City:WARD HILL
State:MA
ZIP:01835-0747
Country:US
Phone:978-521-6300
CAGE:0JVJ1

=============  Composition/Information on Ingredients  =============

Ingred Name:CARBON
CAS:7440-44-0
RTECS #:FF5250100
Fraction by Wt: 100%
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:2 MG/M3 TDUST; 9293

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO	Skin:NO  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:DUST MAY CAUSE IRRITATION TO EYES.
    INHAL: DUST CAUSES IRRITATION AND POSSIBLY ALLERGENIC. INGEST/SKIN:
    NONE KNOWN. CHRONIC: INHALATION: CASES OF PULMONARY FIBROSIS AND
    EMPHYSEMIA HAVE RESULTED FROM PR OLONGED INHALATION OF DUST.
    INGEST: NONE KNOWN.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE KNOWN.

=======================  First Aid Measures  =======================

First Aid:INGEST: NO DATA AVAILABLE BUT ONE SHOULD OBTAIN MEDICAL
    ATTENTION. SKIN: REMOVE CONTAMINATED CLOTHING, FLOOD SKIN WITH
    LARGE AMOUNTS OF WATER. EYE CONTACT: IMMEDIATELY FLUSH EYES,
    INCLUDING UNDER EYEL IDS, WITH LARGE AMOUNTS OF WATER FOR ATLEAST
    15 MINUTES. CALL MD. INHAL: NO SPECIFIC INFORMATION AVAILABLE, ONE
    SHOULD OBTAIN MEDICAL ATTENTION.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:FLAMMABLE SOLID. USE CARBON DIOXIDE, DRY CHEMICAL
    POWDER OR WATER.
Fire Fighting Procedures:COOL CONTAINER W/WATER FROM MAX DISTANCE. WEAR
    NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT. REMOVE MATL
    FROM FIRE AREA IF W/OUT RISK.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

==================  Accidental Release Measures  ==================

Spill Release Procedures:WEARING FULL PROTECTIVE EQUIPMENT, COVER SPILL
    WITH DRY SAND OR VERMICULITE. MIX WELL AND CAREFULLY TRANSFER TO A
    CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP CONTAINER TIGHTLY CLOSED. STORE
    IN A COOL, DRY, WELL-VENTILATED AREA. WASH THOROUGHLY AFTER USE.
Other Precautions:LAB COAT AND APRON, FLAME AND CHEMICAL RESISTANT
    COVERALLS, EYEWASH CAPABLE OF SUSTAINED FLUSHING, SAFETY DRENCH
    SHOWER AND HYGIENIC FACILITIES FOR WASHING.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPROVED HIGH EFFICIENCY PARTICLE
    RESPIRATOR.
Ventilation:LABORATORY FUME HOOD.
Protective Gloves:RUBBER GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:LAB COAT AND APRON, FLAME/CHEMICAL RESISTANT
    COVERALLS, EMERGENCY EYEWASH CAPABLE OF SUSTAINED FLUSHING, DELUGE
    SHOWER.
Work Hygienic Practices:WASH THOROUGHLY AFTER USE.
Supplemental Safety and Health
MATLS TO AVOID: PB(NO3)2, HNO3, K, NA2S, ZN(NO3)2.

==================  Physical/Chemical Properties  ==================

HCC:F8
Boiling Pt:B.P. Text:8721F,4827C
Melt/Freeze Pt:M.P/F.P Text:6606F,3652C
Vapor Pres:0
Spec Gravity:1.8-2.1
Evaporation Rate & Reference:0 (BUTYL ACETATE=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:BLACK POWDER, ODORLESS.
Percent Volatiles by Volume:0

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
OXIDIZING AGENTS, PEROXIDES, NH4NO3, NH4CIO4, BROMATES, CA(OCI)2,
    CHLORATES CL2, CIO,F2, IODATES, IO5 (SUP DATA)
Stability Condition to Avoid:INCOMPATIBLES.
Hazardous Decomposition Products:CO, CO2

====================  Disposal Considerations  ====================

Waste Disposal Methods:CONSULT STATE, LOCAL OR FEDERAL EPA REGULATIONS
    FOR PROPER DISPOSAL.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.