CAROLINA BIOLOGICAL SUPPLY CO -- 84-0467, SEBACOYL CHLORIDE SOLUTION (SEE SUPPL) -- -
===================== Product Identification ===================== Product ID:84-0467, SEBACOYL CHLORIDE SOLUTION (SEE SUPPL) MSDS Date:09/05/2000 FSC:NIIN:Submitter:D DG Status Code:A Kit Part:Y === Responsible Party === Company Name:CAROLINA BIOLOGICAL SUPPLY CO Address:2700 YORK RD City:BURLINGTON State:NC ZIP:27215-3387 Country:US Info Phone Num:800-227-1150/910-584-0381 Emergency Phone Num:800-424-9300 Chemtrec Ind/Phone:(800)424-9300 CAGE:59896 === Contractor Identification === Company Name:CAROLINA BIOLOGICAL SUPPLY CO Address:2700 YORK RD Box:City:BURLINGTON State:NC ZIP:27215-3387 Country:US Phone:800-227-1150/910-584-0381 Contract Num:MDA414-01-P-1321 CAGE:59896 ============= Composition/Information on Ingredients ============= Ingred Name:SEBACOYL CHLORIDE CAS:111-19-3 = Wt:4. OSHA PEL:7 MGM3 (CEILING) ACGIH TLV:7.5 MG/M3 (CEILING) Ingred Name:PETROLEUM ETHER CAS:8032-32-4 RTECS #:OI6180000 = Wt:96. OSHA PEL:300 PPM ACGIH TLV:1370 MG/M3;300 PPM ===================== Hazards Identification ===================== LD50 LC50 Mixture:NO DATA PROVIDED BY MANUFACTURER Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:TARGET ORGANS: EYES, SKIN, LUNGS, RESPIRATORY TRACT. EYES: MAY CAUSE IRRITATION. SKIN: MAY CAUSE IRRITATION. INGESTION: MAY CAUSE GASTROINTESTINAL DISCOMFORT. INHALATION: MAY CAUSE IRRITATION TO RESPI RATORY TRACT. Explanation of Carcinogenicity:NO CHRONIC EFFECTS DATA CITED. NO COMPONENT OF THIS MIXTURE IS LISTED BY ( NTP, IARC,OSHA) AS CAUSING CANCER. Effects of Overexposure:EYES: MAY CAUSE IRRITATION. SKIN: MAY CAUSE IRRITATION. INGESTION: MAY CAUSE GASTROINTESTINAL DISCOMFORT. INHALATION: MAY CAUSE IRRITATION TO RESPIRATORY TRACT. Medical Cond Aggravated by Exposure:NONE KNOWN. ======================= First Aid Measures ======================= First Aid:EYES: FLUSH WITH WATER FOR AT LEAST 15 MINUTES, RAISING & LOWERING LIDS OCCASIONALLY. GET MEDICAL ATTENTION IF IRRITATION PERSISTS. SKIN: THOROUGHLY WASH FOR AT LEAST 15 MINUTES. REMOVE CONTAMINATED C LOTHING. GET MEDICAL ATTENTION IF IRRITATION PERSISTS. INGESTION: DO NOT INDUCE VOMITING. IF SWALLOWED, IF CONSCIOUS, GIVE PLENTY OF WATER IMMEDIATELY AND CALL A PHYSICIAN OR POISON CONTROL CENTER. NO THING BY MOUTH TO AN UNCONSCIOUS PERSON. INHALATION: REMOVE TO FRESH AIR. GIVE OXYGEN IF BREATHING DIFFICULT. GIVER ARTIFICIAL RESPIRATION IF BREATHING STOPPED. GET MEDICAL ATTENTION. ===================== Fire Fighting Measures ===================== Flash Point:=-45.C, -49.F PETROLEUM ETHER Autoignition Temp:=287.C, 548.6F Lower Limits:1.1% Upper Limits:5.9% Extinguishing Media:WATER IS NOT RECOMMENDED. USE DRY CHEMICAL, ALCOHOL FOAM OR CARBON DIOXIDE. Fire Fighting Procedures:FIREFIGHTERS SHOULD WEAR FULL PROTECTIVE EQUIPMENT AND NIOSH APPROVED SELF-CONTAINED BREATHING APPARATUS. Unusual Fire/Explosion Hazard:MAY PRODUCE HAZARDOUS DECOMPOSITION PRODUCTS. CAN REACT VIGOROUSLY WITH OXIDIZING MATERIALS. ================== Accidental Release Measures ================== Spill Release Procedures:VENTILATE AREA OF SPILL. ELIMINATE ALL SOURCES OF IGNITION. REMOVE ALL NON-ESSENTIAL PERSONNEL FROM AREA. CLEAN-UP PERSONNEL SHOULD WEAR PROPER PROTECTIVE EQUIPMENT AND CLOTHING. ABSORB MATERIAL WITH SUITABLE ABSORBENT AND CONTAINERIZE FOR DISPOSAL. Neutralizing Agent:NO DATA PROVIDED BY MANUFACTURER ====================== Handling and Storage ====================== Handling and Storage Precautions:STORE IN TIGHTLY CLOSED CONTAINER. KEEP AWAY FROM HEAT, SPARKS, OR FLAME. OPEN CONTAINER CAUTIOUSLY. DO NOT STORE NEAR COMBUSTIBLES. DO NOT GET IN EYES, ON SKIN, OR ON CLOTHING. EMPTY CONTAINERS MAY C ONTAIN HAZARDOUS RESIDUES. DO NOT REUSE CONTAINER. Other Precautions:DO NOT TAKE INTERNALLY. WASH THOROUGHLY AFTER HANDLING. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:WORK IN FUME HOOD. WEAR NIOSH-MSHA-APPROVED ORGANIC VAPOR RESPIRATOR. Ventilation:LOCAL EXHAUST/MECHANICAL (GENERAL): YES Protective Gloves:RUBBER, NEOPRENE, PVC, OR EQUIVALENT. Eye Protection:SPLASH PROOF CHEMICAL SAFETY GOGGLES SHOULD BE WORN AT ALL TIMES. Other Protective Equipment:LAB COAT, EYE WASH, AND SAFETY SHOWER. Work Hygienic Practices:LAUNDER CONTAMINATED CLOTHING BEFORE REUSE. Supplemental Safety and Health CONTINUED FROM PRODUCT ID: 84-0467, SEBACOYL CHLORIDE SOLUTION AND 84-0467, HEXANEDIAMINE SOLUTION (SERIAL #: CLFBC). HCC FOR KIT IS BASED ON FLASH POINT/BOILING POINT (BP=95F) OF THIS PART AND DLAI 4 145.11, TABLE B-3. ================== Physical/Chemical Properties ================== HCC:F1 Boiling Pt:=35.C, 95.F B.P. Text:PETROLEUM ETHER Solubility in Water:NEGLIGIBLE Appearance and Odor:COLORLESS LIQUID WITH HYDROCARBON ODOR Percent Volatiles by Volume:100% ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES WATER, STRONG OXIDIZERS Stability Condition to Avoid:MOISTURE, HEAT, SPARKS, IGNITION SOURCES, CONTAMINATION. Hazardous Decomposition Products:COX, C12 Conditions to Avoid Polymerization:WILL NOT OCCUR =================== Toxicological Information =================== Toxicological Information:TOXICITY DATA: PETROLEUM ETHER: INTRAVENOUS-MUS LD50: 446 MG/KG. SEBACOYL CHLORIDE: NO TOXICITY DATA FOUND. EFFECTS OF OVEREXPOSURE: SEBACOYL CHLORIDE CAUSES BURNS UPON TISSUE CONTACT. PETROLEUM ETHER CAUSES IRRITATION UPON CONTACT. INHALATION OR INGESTION MAY CAUSE HEADACHE, NAUSEA, VOMITING, DIZZINESS, CENTRAL NERVOUS SYSTEM DEPRESSION. CHRONIC: NO CHRONIC EFFECTS DATA CITED. ===================== Ecological Information ===================== Ecological:EPA WASTE NUMBER(S): D001, D002. ==================== Disposal Considerations ==================== Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS. ALWAYS CONTACT A PERMITTED WASTE DISPOSER (TSD) TO ASSURE COMPLIANCE. ===================== Regulatory Information ===================== SARA Title III Information:HAZARD CATEGORY FOR SARA SECTION 311/312 REPORTING: ACUTE, CHRONIC, FIRE. SARA TITLE III: SEBACOYL CHLORIDE: SARA EHS SECTION 302 TPQ: NO, SARA SECTION 313 CHEMICALS-NAME LIST: NO, SARA SECTION 313 CH EMICALS-CHEMICAL CATEGORY: NO, CERCLA SECTION 103 RQ (LBS): NO, RCRA SECTION 261.33: NO; PETROLEUM ETHER: SARA EHS SECTION 302 TPQ: NO, SARA SECTION 313 CHEMICALS-NAME LIST: NO, SARA SECTION 313 CHEM ICALS-CHEMICAL CATEGORY: NO, CERCLA SECTION 103 RQ (LBS): NO, RCRA SECTION 261.33: NO. Federal Regulatory Information:EPA TSCA STATUS: ON TSCA INVENTORY. State Regulatory Information:NO DATA PROVIDED BY MANUFACTURER. ======================= Other Information ======================= Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.