RADIATOR SPECIALTY COMPANY -- LIQUID WRENCH NON-FLAMM SUPPER LUBRICANT W/TEFLON L3-12 -- 9150-00-973-9504
===================== Product Identification =====================
Product ID:LIQUID WRENCH NON-FLAMM SUPPER LUBRICANT W/TEFLON L3-12
MSDS Date:10/01/1992
FSC:9150
NIIN:00-973-9504
=== Responsible Party ===
Company Name:RADIATOR SPECIALTY COMPANY
Address:1400 W. INDEPENDENCE BLVD.
City:CHARLOTTE
State:NC
ZIP:28208
Info Phone Num:704-377-6555
Emergency Phone Num:704-377-6555
Preparer's Name:T. LIEBMAN, TECH DIR
CAGE:77628
=== Contractor Identification ===
Company Name:RADIATOR SPECIALTY COMPANY
Address:1900 WILKINSON BLVD.
Box:34689
City:CHARLOTTE
State:NC
ZIP:28208
Country:US
Phone:704-377-6555/303-623-5716
CAGE:77628
============= Composition/Information on Ingredients =============
Ingred Name:PERCHLOROETHYLENE (TETRACHLOROETHYLENE) (SARA III)
CAS:127-18-4
RTECS #:KX3850000
Fraction by Wt: 65-80%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:25 PPM
ACGIH TLV:25 PPM/100STEL,A3;94
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS
Ingred Name:CARBON DIOXIDE
CAS:124-38-9
RTECS #:FF6400000
Fraction by Wt: 1-3%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:5000 PPM
ACGIH TLV:5000PPM/30000STEL;94
Ingred Name:MIXTURE OF PETROLEUM HYDROCARBONS (CAS#S:64742-53-6 &
64742-52-5).
Fraction by Wt: 20-30%
Other REC Limits:NONE RECOMMENDED
===================== Hazards Identification =====================
LD50 LC50 Mixture:TLV OF PRODUCT:5MH/M3 AS MIST
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:EYE:MILDLY IRRITATING. SKIN:PROLONGED
CONTACT MAY CAUSE IRRIT/DERM. INHAL:MODERATELY TOXIC, NAUSEA,
DIZZINESS, HEADACHE, CNS DAMAGE. INGET:SLIGHTLY TOXIC, IRRIT OF THE
MOUTH & GI TRACT. PROLONGED EXPO SURE TO HIGH LEVELS MAY BRING ON
OR AGGRAVATED EXISTING LIVER & KIDNEY DAMAGE/DISEASES. MIN HUMAN
EXPOSURE.
Explanation of Carcinogenicity:PER MSDS:PERCHLORETHYLENE CARCINOGEN BY
IARC. PRODUCT KNOWN TO STATE OF CA TO CAUSE CANCER.
Effects of Overexposure:MILD EYE IRRIT. SKIN IRRIT/DERM. MODERATELY
TOXIC WHEN INHAL, NAUSEA, DIZZINESS, HEADACHE, CNS DAMAGE. SLIGHTLY
TOXIC WHEN INGEST, MOUTH & GI TRACT IRRIT.
Medical Cond Aggravated by Exposure:PROLONGED EXPOSURE TO HIGH LEVELS
MAY BRING ON OR AGGRAVATE EXISITNG LIVER & KIDNEY DAMAGE/DISEASES.
======================= First Aid Measures =======================
First Aid:EYE:FLUSH EYES W/WATER FOR 15MINS. SKIN:WASH WITH SOAP/WATER.
REMOVE CONTAMINATED CLOTH/SHOES. INHAL:REMOVE TO FRESHAIR. IF NOT
BREAHTING GIVE ART RESP. IF BREATHING IS DIFFICULT GIVE OXYGEN.
INGEST:I F CONSCIOUS DRINK LG QUANTITIES OF WATER. DO NOT INDUCE
VOMITING. TAKE IMMED TO HOSPITAL OR PHSYCIAN. NEVER ADMINISTER
ADRENALINE FOLLOWING PERCHLOROETHYLENE OVEREXPOSURE.
===================== Fire Fighting Measures =====================
Flash Point Method:COC
Flash Point:DOES NOT FLASH
Extinguishing Media:NON-FLAMMABLE. NONE SPECIFIED BY MFG HOWEVER USE
APPROPRIATE EXTINGUISHING MEDIA FOR SURROUNDING FIRE/MATERIALS.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS &
PROTECTIVE CLOTHES.
Unusual Fire/Explosion Hazard:FIRE MAY CAUSE AEROSOL CANS TO BURST,
EVEN VIOLENTLY. COOL CONTAINERS BY WATER SPRAY.
================== Accidental Release Measures ==================
Spill Release Procedures:VENTILATE AREA, RECOVER W/ADSORBENTS, DIPSOE
OF THROUGH A PERMITTED HAZARDOUS WASTE MANAGEMENT FACILITY.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN COOL, DRY PALCE AWAY FROM
HEAT SOURCES.
Other Precautions:WEARING CONTACT LENS DURING USE IS INADVISABLE. KEEP
AWAY FROM CHILDREN AND ANIMALS. DO NOT PUNCTURE OR INCINERATE CANS.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE FOR CONSUMER. BULK HANDLING:IF TLV IS
EXCEEDED WEAR NIOSH APPROVED RESPIRATOR.
Ventilation:CONSUMER:USE ADEQUATE VENTILATION. BULK HANDLING:GENERAL
VENTIALTION.
Protective Gloves:BULK HANDLING:BUTYL RUBBER GLOVES.
Eye Protection:BULK HANDLING:FULLY PROT GOGG/FACESHIELD
Other Protective Equipment:BULK HANDLING:BUTYL RUBBER APRON.
CONSUMER:NONE.
Work Hygienic Practices:CLEAN CONTAMINATED ITEMS BEFORE REUSE OR
DISCARD.
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
HCC:V6
Boiling Pt:B.P. Text:248F,120C
Vapor Density:5.83
Spec Gravity:1.34
Evaporation Rate & Reference:0.95 (N-BUTYL ACETATE=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:CLEAR, HEAVY LIQUID WITH SWEET ODOR.
Percent Volatiles by Volume:60
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:HDYROGEN CHLORIDE AND POSSIBLE TRACES
OF PHOSGENE.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL APPLICABLE
GOVERNMENT LAWS AND REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their