SCHAEFFER MFG CO -- 266 CITROL -- 7930-00N089538
=====================  Product Identification  =====================

Product ID:266 CITROL
MSDS Date:02/16/1996
FSC:7930
NIIN:00N089538
Status Code:A
=== Responsible Party ===
Company Name:SCHAEFFER MFG CO
Address:102 BARTON ST
City:ST LOUIS
State:MO
ZIP:83104
Country:US
Info Phone Num:314-966-5681
Emergency Phone Num:800-325-9962
CAGE:0DUG2
=== Contractor Identification ===
Company Name:SCHAEFFER MFG CO
Address:102 BARTON ST
Box:City:ST LOUIS
State:MO
ZIP:63104
Country:US
Phone:314-966-5681
CAGE:0DUG2

=============  Composition/Information on Ingredients  =============

Ingred Name:D-LIMONENE (MFR CAS # 15989-27-5)
CAS:5989-27-5
RTECS #:GW6360000
Fraction by Wt: 35-45%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:DIETHANOLAMINE (SARA 313) (CERCLA)
CAS:111-42-2
RTECS #:KL2975000
Fraction by Wt: 1-3%
OSHA PEL:3 PPM
ACGIH TLV:0.46 PPM; 9495
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Ingred Name:GLYCOLS, POLYETHYLENE, MONO (NONYLPENYL) ETHER;
    (POLY(OXY-1-2-ETHANEDLYL-NONYLPHERRYL)-OMEGA-HYDROXY-)
CAS:9018-45-9
RTECS #:MD0900000
Fraction by Wt: 3-5%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:2-BUTOXYETHANOL
CAS:111-76-2
RTECS #:KJ8575000
Fraction by Wt: 10-15%
OSHA PEL:S, 50 PPM
ACGIH TLV:S, 25 PPM; 9495

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ANIMAL STUDIES CLEARLY DEMONSTRATED
    DOSE-RELATED ADVERSE EFTS ON CNS, HEMATOPOIETIC TISSUES, BLOOD,
    KIDNEYS & LIVER, ASSOC W/ADMIN OF ETHYLENE GLYCOL MONOBUTYL ETHER
    ACETATE (EGBEA). (EXTRACTED FROM D HHS (NIOSH) PUB NO 90-118) .
    ACUTE: INGEST: HARMFUL IF INGESTED. THIS PROD IS CORR TO MOUTH &
    (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: ESOPHAGUS IF SWALLOWED. EYE: AT HIGH
    CONC WHEN HEATED VAPS ARE IRRIT TO EYES, LIQ CNTCT PRODUCES SEV
    IRRIT & POSS EYE BURNS. SKIN: SLIGHTLY IRRIT W/POSS REDNESS,
    EDEMA/DRYNESS TO SKIN. INHAL : INHAL OF VAPS OF MIST MAY CAUSE
    DIZZ,DORW & IRRIT TO THE MUCS MEMBS. CHRONIC: DIETHANOLAMINE HAS
    BEEN (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INGESTION: DO NOT INDUCE VOMITING. DRINK MILK OR WATER TO
    DILUTE. SEEK MEDICAL ATTENTION IMMEDIATELY. SKIN: REMOVE
    CONTAMINATED CLOTHING. WASH SKIN WITH COPIOUS AMOUNTS OF SOAP AND
    WATER. LAUNDER CONT AMINATED CLOTHING. INHALATION: REMOVE VICTIM TO
    FRESH AIR. IF BREATHING IS DIFFICULT, ADMINISTER OXYGEN. EYES:
    IMMEDIATELY FLUSH WITH CLEAR, COOL, CLEAN WATER FOR 30 MINUTES.
    SEEK MEDICAL ATTN IMMED.

=====================  Fire Fighting Measures  =====================

Flash Point Method:COC
Flash Point:145F,63C
Extinguishing Media:CARBON DIOXIDE OR DRY CHEMICAL FOAM, SAND, EARTH
    WATERFOG.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT . TREAT AS A CLASS B FIRE. AVOID BREATHING FUMES.
Unusual Fire/Explosion Hazard:VAPORS CAN BE DENSER THAN AIR AND TRAVEL
    BACK TO IGNITION SOURCE CAUSING FLASHBACK TO OCCUR.

==================  Accidental Release Measures  ==================

Spill Release Procedures:ABSORB SPILLS WITH ABSORBENT MATERIAL.
    VENTILATE CONFINED SPACES. LARGE SPILLS SHOULD BE DIKE THEN PUMPED
    INTO A TANK TRUCK OR DRUMS FOR DISPOSAL. AFTER MATERIAL HAS BEEN
    REMOVED, FLUSH CONTAMINATED A REA WITH LARGE AMOUNTS OF WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:DO NOT STORE NEAR HEAT, SPARKS OR OPEN
    FLAMES. KEEP CONTAINER CLOSED WHEN PRODUCT IS NOT IN USE. FLAMMABLE
    ACCORDING TO CURRENT DOT REGULATIONS.
Other Precautions:SPECIAL COMMENTS: THIS PRODUCT IS A COMBUSTIBLE
    LIQUID. DO NOT REUSE CONTAINER. DISPOSE OF THE CONTAINER IN
    ACCORDANCE WITH LOCAL, STATE AND FEDERAL EPA REGULATIONS. DO NOT
    STORE NEAR FOOD PRODUCTS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE REQUIRED UNDER ORDINARY CONDITIONS OF USE.
    NIOSH APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:NO SPECIAL REQUIREMENT UNDER ORDINARY CONDITIONS OF USE AND
    WITH ADEQUATE VENTILATION.
Protective Gloves:SOLVENT RESISTENT NEORPENE/RUB GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
    ANSI DESIGN CRITERIA . USE APRON & BOOTS AS REQUIRED.
Work Hygienic Practices:LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
    WASH THOROUGHLY WITH SOAP AND WATER AFTER USE.
Supplemental Safety and Health
EFTS OF OVEREXP: LINKED TO LIVER AND KIDNEY DAMAGE IN ANIMAL STUDIES.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:>212F,>100C
Spec Gravity:0.9313
pH:9
Solubility in Water:SOLUBLE
Appearance and Odor:THIS PRODUCT IS AVAILABLE IN SPRAY CANS.
Percent Volatiles by Volume:70

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:HIGH HEAT, SPARKS & OPEN FLAMES.
Hazardous Decomposition Products:CARBON MONOXIDE, ALDEHYDES AND
    KETONES.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL APPLICABLE
    FEDERAL, STATE AND LOCAL LAWS & REGULATIONS. FOR SPENT PRODUCT,
    ALLOW OILS AND OILY WASTES TO SPARATE, SKIM OFF TOP OIL LAYER AND
    DISCHARGE BOTTOM LAYER IN  ACCORDANCE WITH EPA, FEDERAL, STATE &
    LOCAL REGS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.