CALCOMP -- 17135-0036, ELECTROSTATIC TONER PREMIX, (SUPP DATA) -- 6850-00N035144
===================== Product Identification ===================== Product ID:17135-0036, ELECTROSTATIC TONER PREMIX, (SUPP DATA) MSDS Date:06/16/1995 FSC:6850 NIIN:00N035144 === Responsible Party === Company Name:CALCOMP Address:2411 WEST LA PALMA AVE City:ANAHEIM State:CA ZIP:92801 Country:US Info Phone Num:714-821-2556 Emergency Phone Num:800-424-9300(CHEMTREC) CAGE:IO122 === Contractor Identification === Company Name:CALCOMP Address:2411 W LA PALMA AVE Box:3250 City:ANAHEIM State:CA ZIP:92803 Country:US Phone:714-821-2290 CAGE:IO122 Company Name:CALIFORNIA COMPUTER PRODUCTS SUB OF SANDERS ASSOC Address:2411 W LA PALMA AVE Box:3250 City:ANAHEIM State:CA ZIP:92803 Country:US CAGE:14668 ============= Composition/Information on Ingredients ============= Ingred Name:ING 8:COMBINATIONS OF EQUIP, OFFICE VENT MAY NOT BE ADEQ. USERS SHOULD ASSURE THAT VENT IS SUFFICIENT TO PVNT (ING 10) RTECS #:9999999ZZ Ingred Name:ING 9:EXCEEDING EXPOS LIMS. USERS SHOULD CONSULT QUALIFIED VENT ENGINEER &/OR INDUSTRIAL HYGIENIST IF A CONCERN (ING 11) RTECS #:9999999ZZ Ingred Name:ING 10:REGARDING EXPOSURE ARISES. RTECS #:9999999ZZ Ingred Name:MINERAL SPIRITS; (MIXED C*8 - C*12 ALKANE ISOMERS, N.O.S.) (ISOPARAFFINIC PETROLEUM SOLVENT (HYDROCARBON DISTILLATE)) CAS:64475-85-0 RTECS #:PY8240000 Fraction by Wt: >98% Other REC Limits:300 PPM (MFR) OSHA PEL:N/K ACGIH TLV:N/K Ingred Name:ACRYLIC POLYMER/RESIN; (ACRYLIC COPOLYMER/RESIN) CAS:28430-58-2 Fraction by Wt: <1% OSHA PEL:N/K ACGIH TLV:N/K Ingred Name:2-NAPHTHALENECARBOXYLIC ACID, 3HYDROXY4 [4-METHYL2SULFOPHENYL)AZO)-, CALSIUM SALT(1:1); (RED (PIGMENT)) CAS:5281-04-9 Fraction by Wt: <1% OSHA PEL:N/K ACGIH TLV:N/K Ingred Name:OTHER PREC:PLOTTERS. EXPOS TO VAPS & FIRE HAZ SHOULD BE MIN WHEN STORED PROPERLY & USED AS DIRECTED W/CALCOMP (ING 5) RTECS #:9999999ZZ Ingred Name:ING 4:EQUIP. PROD WILL STAIN CLTHG & SKIN, PRECS SHOULD BE TAKEN BY USERS TO PVNT CONT. PROPER VENT OF ROOM WHERE(ING 6) RTECS #:9999999ZZ Ingred Name:ING 5:PLOTTERS ARE OPERATING WILL PVNT VAP ACCUM. PROD IS TO BE STORED IN COOL, DRY PLACE TO PVNT DETERIORATION. (ING 7) RTECS #:9999999ZZ Ingred Name:ING 6:DURING A FIRE, PRODUCT CAN ESCAPE & PRESENT AN ADDITIONAL FIRE HAZARD. RTECS #:9999999ZZ Ingred Name:VENT:AIR CONDITIONING ENGINEERS (ASHRAE) 1980 STDS IS ADEQ UNDER NORMAL CNDTNS OF USE. UNDER SOME CNDTNS OF USE/ (ING 9) RTECS #:9999999ZZ ===================== Hazards Identification ===================== LD50 LC50 Mixture:LD50:(ORAL,RAT) 5 G/KG. Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:ACUTE:EYE:IRRITANT - MAY CAUSE CONJUNCTIVITIS. SKIN:PROLONGED CONTACT CAUSES DEFATTING, DRYING, CRACKING, DERMATITIS. INHALATION:NOT NORMALLY A HAZARD. OVEREXPOSURE BY INHALATION MAY CAUSE HEADACHE, N AUSEA AND RESPIRATORY IRRITATION. INGESTION:NAUSEA AND POSSIBLE GASTRO-INTESTINAL IRRITATION. CHRONIC: (EFTS OF OVEREXP) Explanation of Carcinogenicity:NOT RELEVANT Effects of Overexposure:HLTH HAZ:RPTD INHAL EXPOSURE TO RATE OF A SIMILAR HYDROCARBON AT CONCS GREATER THAN OR EQUAL TO 300 PPM IN AIR CAUSED LOW GRADE (MILD) ANEMIA & KIDNEY EFTS. TARGET ORGANS:EYES, SKIN, RESPIRATORY SYSTE M. TOX DATA:THIS MATL HAS BEEN EXTENSIVELY TESTED. WHEN USED AS INTENDED, IT DOES NOT REPRESENT ANY KNOWN HLTH/SFTY HAZ. Medical Cond Aggravated by Exposure:PERS W/PRE-EXISTING HEALTH CONDITIONS OF DERMATITIS & RESP AILMENTS MAY NOTICE PHYSICAL REACTIONS WHEN EXPOSED TO SMALL AMOUNTS OF PROD/VAP. CONSULT THEIR TREATING MD FOR PROPER ACTION AFTER EXPOSURE. ======================= First Aid Measures ======================= First Aid:EYES:FLUSH W/LG AMTS OF WATER FOR AT LST 15 MINS/UNTIL IRRIT SUBSIDES, INCL UNDER LIDS. IF IRRIT PERSISTS, CONT MD. SKIN:REMOVE CONTAM CLTHG. WASH SKIN THORO W/SOAP & WATER. DO NOT REUSE CONTAM CLTHG UNTIL SOLVS HAVE BEEN REMOVED. INHAL:MOVE VICTIM TO FRESH AIR. CALL MD IMMED. IF BRTHG IS IRREG/STOPPED, START RESUSCITATION IF TRAINED. ADMIN OXYG IF AVAIL. INGEST:DO NOT INDUCE VOMIT DUE TO (SUPDAT) ===================== Fire Fighting Measures ===================== Flash Point Method:TCC Flash Point:>102F,>39C Lower Limits:0.8% Upper Limits:7% Extinguishing Media:FOAM, DRY CHEMICAL, CO*2 (CARBON DIOXIDE), WATER FOG. Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE EQUIPMENT . AVOID WATER, IT TENDS TO SPREAD HYDROCARBON FIRES. Unusual Fire/Explosion Hazard:COMBUSTIBLE LIQUID, CAN FORM COMBUSTIBLE MIXTURES AT OR ABOVE THE FLASHPOINT. ================== Accidental Release Measures ================== Spill Release Procedures:REMOVE IGNITION SOURCES. COLLECT ON INERT ABSORBENT MATERIAL. PLACE IN WASTE CONTAINER APPROVED FOR COMBUSTIBLE WASTE. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:STORE IN CLSD, COOL, WELL VENTED AREA, AWAY FROM HEAT & FLAME. READ & FOLLOW LBL PRECS. DO NOT REUSE CNTNR. KEEP CNTNRS CLSD WHEN NOT IN USE. Other Precautions:FLAMM LIQ. DO NOT SMOKE WHEN USING PROD. MIN BRTHG VAP/MIST. USE W/ADEQ VENT. AVOID PRLNG/RPTD SKIN CONT. "EMPTY" CNTNRS RETAIN RESIDUE (LIQ &/OR VAP) & CAN BE DANGEROUS. DISP OF PROPERLY. MANUFACTURE D & BOTTLED FOR USE IN CALCOMP (ING 4) ============= Exposure Controls/Personal Protection ============= Respiratory Protection:NOT REQUIRED WHEN USED AS INTENDED. IN CONCENTRATIONS EXCEEDING RECOMMENDED SAFE EXPOSURE LIMIT, SUCH AS DURING A MAJOR SPILL, USE A NIOSH APPROVED CHEMICAL CARTRIDGE RESPIRATOR EFFECTIVE FOR ORGANIC VAPORS. Ventilation:LOC EXHST; TO MAINTAIN BELOW TLV. NORMAL OFFICE VENT CONFORMING TO AMERICAN SOCIETY OF HEATING, REFRIGERATING & (ING 8) Protective Gloves:LATEX GLOVES FOR OVEREXP. USE (SUPDAT) Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS . Other Protective Equipment:ANSI APPRVD EYE WASH FOUNTAIN & DELUGE SHOWER . WEAR CHEM RESIST APRON WHEN CLEANING MACHINES AS PROD MAY (SUPDAT) Work Hygienic Practices:WHEN HANDLING CHEMICALS, ALWAYS USE GOOD PERSONAL HYGIENE PRACTICES, SUCH AS WASHING YOUR HANDS AFTER USING PRODUCT. Supplemental Safety and Health MFR'S TRADE NAME/PART NO:MAGENTA, TPM-68M. FIRST AID PROC:ASPIR HAZ. CALL MD. WASTE DISP METH:CONTROL AGENCY FOR ASSISTANCE. RCRA HAZ WASTE #:D001. PROT GLOVES:PROT GLOVES, SUCH AS NITRILE/NEOPRENE, W HEN CONT W/LIQ MAY OCCUR, SUCH AS WHEN PURGING, CLEANING/HNDLG CNTNRS. OTHER PROT EQUIP:STAIN CLOTHING. ================== Physical/Chemical Properties ================== Boiling Pt:B.P. Text:>320F,>160C Vapor Pres:1 @ 20C Vapor Density:5 Spec Gravity:0.76 (H*2O=1) Evaporation Rate & Reference:0.25-0.45 (N-BUAC=1) Solubility in Water:IMMISCIBLE Appearance and Odor:MAGENTA (PURPLISH RED) LIQUID W/SLIGHT PETROLEUM HYDROCARBON ODOR. Percent Volatiles by Volume:80-100 ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES VERY STRONG OXIDANTS LIKE CHROMIC ACID OR LIQUID CHLORINE. Stability Condition to Avoid:NONE. Hazardous Decomposition Products:NONE. ==================== Disposal Considerations ==================== Waste Disposal Methods:WASTE TONERS & REPLENISHERS ARE HAZ WASTES AS DEFINED BY 40 CFR CHAPTER 1 (FLAMMABILITY). TREAT AS HAZ WASTE & DISP OF I/A/W ALL APPLIC FED, STATE & LOC DISP REG. DO NOT POUR DOWN COMMON DRAIN. CONT L ICENSED HAZ WASTE DISP COMPANY/ENVIRON (SUPP DATA) Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.